LADAR and LIDAR Detector Systems

APD and LADAR Detector Arrays

• Sensitivity from below 950 nm out to 1700 nm
• Back-illuminated mesa architecture allows for fast optical overload recovery
• Available for all of Voxtel’s APD families (BSI Deschutes, Siletz, and UHG Siletz)
• High uniformity of breakdown voltage
• Low pixel defect counts
• Array sizes from 2×2 up to 640×480
• Pixel sizes ranging from 10×10 µm2 to 1×1 mm2
• Radiation-tolerant designs

APDs and LADAR ROICs

Voxtel has broad experience in optical receiver and focal plane array circuit design, which we bring to bear to solve our customers’ difficult problems. A majority of our readout integrated circuits (ROICs) are fabricated using domestic (United States) trusted foundry sources. Many designs include features for increased radiation tolerance and reduced power consumption.

• MHz- to multi-GHz-response amplifiers, allowing nanosecond laser pulse response
• Pixel sizes ranging from 10×10 to 100×100 µm2
• Frame rates up to tens of kHz
• Designs for either integrated-signal wavefront/range-gated imaging or sub-nanosecond pulse detection
• Pulse detection circuits with <250 ps time of flight (TOF) record
• Multiple records per frame: e.g. sampling of three or more pulse amplitude and TOF pairs (first, peak, and last, or first and last three, etc.)
• Radiation-hardened designs

Voxtel ROICs

Part Number Application Description Pixel Pitch [µm] Array Format Frame Rate Timing Resolution Jitter No. Samples per Frame Dynamic Range Noise Level
VX-240 Single Photon LADAR 2D Array Records both time of arrival & amplitude 36 32 × 32 10 kHz 250 ps 2 (time & amplitude) 12 bits time 45 e-
VX-251 Single Photon LADAR Linear Array Time of arrival & amplitude w/ in-pixel gain uniformity correction 100 8 × 1 30 kHz 250 ps 32 × time and amplitude 20 bits time 35 e-
VX-279 Geiger-Mode (GM) APD Active Quenching Circuit (AQC) GM AQC (16 ns to 1 µs) 1,000 1 Cont. 16 ps NA 1M CPS NA
VX-283 Geiger-Mode APD AQC GM AQC (16 ns to 1 µs) 36 8 × 8 Cont. 50 ps NA 1M CPS NA
VX-286 Pushbroom Underwater Waveform Recording Ripple sample (<1 ns) 35 × Y 256 × 1 400 Hz 2.5 ns 128 × amplitude 14 bits ampl. 150 e-
VX-289 Geiger-Mode APD AQC GM AQC (16 ns to 1 µs) 36 8 × 8 Cont. 50 ps NA 1M CPS NA
VX-297 APD Wavefront FPA Snapshot integrator 36 32 × 32 20 kHz 50 ns 1 × amplitude 12.5 bits 100 e-
VX-797 14-bit Pipeline ADC ADC NA 1 40 MSPS NA NA 14 bits NA
VX-216 NIR Pulsed Laser Imaging FPA (<4 ns) Snapshot integrator, w/ <4 ns integrn. 10 320 × 256 350 Hz 10 ns 1 × amplitude 11 bits ampl. 75 e-
VX-798 X-ray Photon Counter X-ray photon counting (<3-ns response) 130 48 × 48 140 Hz 11.4 ns 2 × 15-bit counters 30 bits count 40 e-
VX-266 High-Rate UAV LADAR & Ranging Detector Time of arrival & amplitude NA 1 10 kHz 250 ps / 2 ns 1 × time and amplitude 12 bits time 25 e-
VX-801 Cherenkov SiPM Imaging Array High-res. back illuminated SiPM with high count rate 25 14 × 14 Cont. <500 ps Photon number N/A N/A
VX-802 Low Light Level Star Tracking Array Snapshot integrator 15 1024 × 1024 10 Hz 1 µs 1 × amplitude 12 bits ampl. 20 e-
VX-803 Charged Particle Time of Arrival & Spatial Tracking Time of arrival 15 960 × 448 5 Hz 300 ns 1 × time 12 bits time 20 e-
VX-804 LADAR 2D Focal Plane Time of arrival & amplitude 30 32 × 32 10 kHz 350 ps / 3 ns 3 × time and amplitude 12 bits time 40 e-
VX-805 Fast Laser Rangefinding/ LIDAR Time of arrival & amplitude 100 × Y 1 1.5 MHz 100 ps / 500 ps 8 × time and amplitude 11.5 bits time ?